Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Hosp Infect ; 134: 89-96, 2023 Apr.
Article in English | MEDLINE | ID: covidwho-2220983

ABSTRACT

Regulations for measures to protect against SARS-CoV-2 transmission vary widely around the world, with very strict regulations in Germany where respirators (filtering face piece FFP2 or comparable) are often mandatory. The efficiency of respirators, however, depends essentially on the tight facial fit avoiding the bypass of contaminated air via gaps between mask and wearer's face. The facial fit can be verified in a fit test. The aim of this review was to describe the quantitative fit test results depending on the respirator designs. A literature search revealed 29 suitable studies. Of all respirators with circumferential head straps, three-panel folded dome-shaped respirators showed the best fit (80.8% of 4625 fit tests passed), followed by rigid-dome-shaped respirators (72.4% of 8234 fit tests passed), duckbill-shaped respirators (31.6% of 2120 fit tests passed), and coffee-filter-shaped respirators (30.9% of 3392 fit tests passed). Respirators with ear loops showed very poor tight fit (3.6% of 222 fit tests passed). In four randomized control trials, single-use respirators were not shown to be superior to surgical masks for the prevention of laboratory-confirmed viral respiratory infections, even when adjusted with a fit test. Therefore, we consider the mandatory use of respirators to be disproportionate and not supported by evidence. Further evidence should be generated, in which scenarios respirators might provide an effective benefit as part of occupational health and safety. For situations with confirmed benefits, only high-quality disposable respirators with head straps or respiratory protective equipment of higher protective levels should be used.


Subject(s)
COVID-19 , Occupational Exposure , Respiratory Protective Devices , Humans , COVID-19/prevention & control , SARS-CoV-2 , Equipment Design , Masks , Ventilators, Mechanical , Occupational Exposure/prevention & control
3.
J Hosp Infect ; 113: 104-114, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1531580

ABSTRACT

Healthcare-associated infections (HAIs) are the most common adverse outcomes due to delivery of medical care. HAIs increase morbidity and mortality, prolong hospital stay, and are associated with additional healthcare costs. Contaminated surfaces, particularly those that are touched frequently, act as reservoirs for pathogens and contribute towards pathogen transmission. Therefore, healthcare hygiene requires a comprehensive approach whereby different strategies may be implemented together, next to targeted, risk-based approaches, in order to reduce the risk of HAIs for patients. This approach includes hand hygiene in conjunction with environmental cleaning and disinfection of surfaces and clinical equipment. This review focuses on routine environmental cleaning and disinfection including areas with a moderate risk of contamination, such as general wards. As scientific evidence has not yet resulted in universally accepted guidelines nor led to universally accepted practical recommendations pertaining to surface cleaning and disinfection, this review provides expert guidance for healthcare workers in their daily practice. It also covers outbreak situations and suggests practical guidance for clinically relevant pathogens. Key elements of environmental cleaning and disinfection, including a fundamental clinical risk assessment, choice of appropriate disinfectants and cleaning equipment, definitions for standardized cleaning processes and the relevance of structured training, are reviewed in detail with a focus on practical topics and implementation.


Subject(s)
Cross Infection , Disinfectants , Cross Infection/prevention & control , Delivery of Health Care , Disinfection , Equipment Contamination/prevention & control , Humans , Hygiene
4.
Viruses ; 13(4):12, 2021.
Article in English | MEDLINE | ID: covidwho-1210015

ABSTRACT

So far, only a few reports about reinfections with SARS-CoV-2 have been published, and they often lack detailed immunological and virological data. We report about a SARS-CoV-2 reinfection with a genetically distinct SARS-CoV-2 variant in an immunocompetent female healthcare worker that has led to a mild disease course. No obvious viral escape mutations were observed in the second virus variant. The infectious virus was shed from the patient during the second infection episode despite the presence of neutralizing antibodies in her blood. Our data indicate that a moderate immune response after the first infection, but not a viral escape, did allow for reinfection and live virus shedding.

5.
J Hosp Infect ; 112: 108-113, 2021 Jun.
Article in English | MEDLINE | ID: covidwho-1185068

ABSTRACT

BACKGROUND: The presence of coronaviruses on surfaces in the patient environment is a potential source of indirect transmission. Manual cleaning and disinfection measures do not always achieve sufficient removal of surface contamination. This increases the importance of automated solutions in the context of final disinfection of rooms in the hospital setting. Ozone is a highly effective disinfectant which, combined with high humidity, is an effective agent against respiratory viruses. Current devices allow continuous nebulization for high room humidity as well as ozone production without any consumables. AIM: In the following study, the effectiveness of a fully automatic room decontamination system based on ozone was tested against bacteriophage Φ6 (phi 6) and bovine coronavirus L9, as surrogate viruses for the pandemic coronavirus SARS-CoV-2. METHODS: For this purpose, various surfaces (ceramic tile, stainless steel surface and furniture board) were soiled with the surrogate viruses and placed at two different levels in a gas-tight test room. After using the automatic decontamination device according to the manufacturer's instructions, the surrogate viruses were recovered from the surfaces and examined by quantitative cultures. Then, reduction factors were calculated. FINDINGS: The ozone-based room decontamination device achieved virucidal efficacy (reduction factor >4 log10) against both surrogate organisms regardless of the different surfaces and positions confirming a high activity under the used conditions. CONCLUSION: Ozone is highly active against SARS-CoV-2 surrogate organisms. Further investigations are necessary for a safe application and efficacy in practice as well as integration into routine processes.


Subject(s)
Automation/instrumentation , COVID-19/prevention & control , Disinfectants/pharmacology , Disinfection/instrumentation , Disinfection/methods , Ozone/pharmacology , Animals , Bacteriophages/drug effects , COVID-19/transmission , Cattle , Coronavirus, Bovine/drug effects , Cross Infection/prevention & control , Cross Infection/virology , Decontamination/instrumentation , Decontamination/methods , Equipment and Supplies, Hospital/virology , Hospitals , Humans , SARS-CoV-2/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL